內(nèi)窺鏡清潔保養(yǎng)的步驟

來源:http://m.tukouzhao.cn/ 發(fā)布時(shí)間:2024-06-06 瀏覽量:0

1:使用軟毛巾或紗布在流動(dòng)自來水下擦拭表面,去除污漬和血跡。使用大號(hào)和小號(hào)軟毛刷分別清潔工作通道和左右灌洗通道。

1: Use a soft towel or gauze to wipe the surface under running tap water to remove stains and blood. Use a large and small soft bristled brush to clean the working channel and left and right irrigation channels respectively.

2:使用大號(hào)注射器或高壓水槍清潔灌洗通道和工作通道。

2: Use a large syringe or high-pressure water gun to clean the filling and working channels.

3:將內(nèi)窺鏡置于浸泡箱,去污漬生物酶稀釋液內(nèi)浸泡5min。

20200426035244690

3: Place the endoscope in a soaking box and soak it in a stain removing enzyme diluent for 5 minutes.

4:重復(fù)第一步和第二步。確保內(nèi)外表面和腔道清潔光滑,無血污;物鏡和目鏡徹底清潔。

4: Repeat the first and second steps. Ensure that the inner and outer surfaces and cavities are clean, smooth, and free of blood stains; Thoroughly clean the objective lens and eyepiece.

5:用去離子水(蒸餾水、反滲水等)再次沖洗內(nèi)窺鏡的內(nèi)外表面和腔道,若缺少此步驟,滅菌后將在內(nèi)外表面殘留水漬。

5: Rinse the inner and outer surfaces and lumens of the endoscope again with deionized water (distilled water, reverse osmosis water, etc.). If this step is missing, water stains will remain on the inner and outer surfaces after sterilization.

6:將內(nèi)窺鏡置于干燥箱烘干(不超過60°),若缺少此步驟,等離子滅菌時(shí)可能造成損壞;高溫滅菌后可能殘留水漬。

6: Place the endoscope in a drying oven (not exceeding 60 ° C) for drying. If this step is missing, it may cause damage during plasma sterilization; Water stains may remain after high-temperature sterilization.

7:將醫(yī)用潤滑劑涂抹于干紗布,擦拭內(nèi)窺鏡的外表面(物鏡和目鏡除外);用注射器噴涂少許醫(yī)用潤滑劑于內(nèi)窺鏡的內(nèi)部腔道。

7: Apply medical lubricant to dry gauze and wipe the outer surface of the endoscope (excluding the objective and eyepiece); Spray a small amount of medical lubricant onto the internal cavity of the endoscope using a syringe.

本文由內(nèi)窺鏡設(shè)備維修友情奉獻(xiàn).更多有關(guān)的知識(shí)請(qǐng)點(diǎn)擊:http://m.tukouzhao.cn真誠的態(tài)度.為您提供為全面的服務(wù).更多有關(guān)的知識(shí)我們將會(huì)陸續(xù)向大家奉獻(xiàn).敬請(qǐng)期待.

This article is dedicated to the maintenance of endoscopic equipment. For more information, please click: http://m.tukouzhao.cn Sincere attitude. We will provide you with comprehensive service. We will gradually contribute more relevant knowledge to everyone. Stay tuned

s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話:13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國際信息產(chǎn)業(yè)園6號(hào)樓101-2室
  • 匠仁醫(yī)療湖南長沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國際信息產(chǎn)業(yè)園6號(hào)樓101-2室  湖南省長沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號(hào)