歡迎來到匠仁醫(yī)療設(shè)備有限公司網(wǎng)站!

更多 > 新聞資訊
公司新聞
行業(yè)知識(shí)
檢測(cè)答疑
圖標(biāo) 首頁 >> 新聞資訊 > 行業(yè)知識(shí)

行業(yè)知識(shí)

醫(yī)用內(nèi)窺鏡要在哪些部位進(jìn)行保養(yǎng)

來源:http://m.tukouzhao.cn/ 發(fā)布時(shí)間:2023-07-04 瀏覽量:0

在醫(yī)院各科室中,內(nèi)窺鏡的使用非常嚴(yán)格。下面內(nèi)窺鏡維修公司人員為您講講醫(yī)用內(nèi)窺鏡要在哪些部位進(jìn)行保養(yǎng)。
In various departments of the hospital, the use of endoscopes is very strict. Below, the personnel of the endoscope maintenance company will explain to you which parts of the medical endoscope should be maintained.
內(nèi)窺鏡對(duì)使用環(huán)境的要求:
Requirements for the operating environment of endoscopes:
室內(nèi)環(huán)境以暗室環(huán)境為主,避免強(qiáng)光直射,手術(shù)開始關(guān)閉日光燈,用無影燈照明,術(shù)前室內(nèi)的溫度保持在22~25C、濕度50%左右、防酸、防堿、防蒸氣。避免強(qiáng)電、電磁場(chǎng)的干擾。手術(shù)中確保電壓穩(wěn)定,連續(xù)穩(wěn)壓器維持電壓220V以免損壞精密儀器。
The indoor environment is dominated by dark room environment to avoid direct glare. The fluorescent lamp is turned off and shadowless lamp is used for lighting at the beginning of the operation. The temperature in the room before the operation is kept at 22~25C, the humidity is about 50%, and the room is acid proof, alkali proof, and vapor proof. Avoid interference from strong electricity and electromagnetic fields. Ensure voltage stability during surgery, and maintain a continuous voltage regulator of 220V to prevent damage to precision instruments.
室內(nèi)儀器定位放置:
Indoor instrument positioning and placement:
手術(shù)間的電源插座應(yīng)為屋頂懸掛式,避免因工作人員走動(dòng)碰脫電源插座而使電源線受干擾,保證手術(shù)的順利進(jìn)行,同時(shí)也避免由于電壓不穩(wěn)而造成儀器損壞。
The power socket in the operating room should be a rooftop suspended type to avoid interference with the power cord caused by personnel moving and touching the power socket, ensuring the smooth progress of the surgery, and also avoiding instrument damage due to unstable voltage.
內(nèi)窺鏡維修公司
監(jiān)視器:
Monitor:
一般監(jiān)視器在安裝時(shí)已經(jīng)都是有相關(guān)技術(shù)人員進(jìn)過測(cè)試并調(diào)整到了好的顯示狀態(tài),所以不建議使用者自行調(diào)試。
Generally, monitors have been tested and adjusted to a good display state by relevant technical personnel during installation, so it is not recommended for users to debug on their own.
如果監(jiān)視器不顯示,請(qǐng)檢查插線板和電源線的連接,顯示器開關(guān)是否處于打開狀態(tài)、攝像系統(tǒng)是否處于打開狀態(tài)、攝像系統(tǒng)的輸出是否正確的連接到監(jiān)視器的輸入端口。
If the monitor does not display, please check the connection between the patch panel and power cord, whether the monitor switch is on, whether the camera system is on, and whether the output of the camera system is correctly connected to the input port of the monitor.
顏色失真后可將攝像系統(tǒng)的光學(xué)接口對(duì)準(zhǔn)顏色比較鮮明的物體或圖片,通過監(jiān)視器上的菜單進(jìn)行對(duì)比度、飽和度、亮度的調(diào)節(jié)。避免強(qiáng)磁物體靠近監(jiān)視器,定期作消磁保養(yǎng),當(dāng)磁化嚴(yán)重或消磁失效的時(shí)候,請(qǐng)聯(lián)系廠家技術(shù)人員。
After color distortion, the optical interface of the camera system can be aimed at objects or images with bright colors, and contrast, saturation, and brightness can be adjusted through the menu on the monitor. Avoid strong magnetic objects approaching the monitor and regularly perform demagnetization maintenance. In case of severe magnetization or demagnetization failure, please contact the manufacturer's technical personnel.
攝像系統(tǒng)和光源:
Camera system and light source:
雖說很多內(nèi)窺鏡聲明光學(xué)接口是防水的,但光學(xué)接口和連接線不建議消毒,每次使用時(shí)消毒套,這樣可以增加光學(xué)接口的使用壽命,如需要消毒請(qǐng)用低溫需蒸的方法。
Although many endoscopes declare that the optical interface is waterproof, it is not recommended to disinfect the optical interface and connecting wires. Disinfect the sleeve every time it is used, which can increase the service life of the optical interface. If disinfection is needed, please use a low-temperature steam method.
插口不能強(qiáng)插拔,要對(duì)準(zhǔn)十二點(diǎn)的位置進(jìn)行直插、直拔輕拿輕放,定期作白平衡校準(zhǔn)。
The socket cannot be forcefully inserted or unplugged. It should be aligned with the position at twelve o'clock for direct insertion, direct extraction, and gentle handling. Regular white balance calibration should be performed.
防止光學(xué)接口接觸液體,即使聲稱是防水的設(shè)備,所以不要將調(diào)焦頭及連線浸泡消毒,如不甚接觸葡萄糖-類的液體請(qǐng)手術(shù)后立即用干布擦干凈光學(xué)接口表面液體。
Prevent the optical interface from coming into contact with liquids, even if claimed to be waterproof equipment, so do not soak and disinfect the focusing head and wiring. If there is little contact with glucose like liquids, please immediately wipe the surface liquid of the optical interface with a dry cloth after surgery.
防止卡口結(jié)晶運(yùn)動(dòng)不靈活,如果出現(xiàn)異常請(qǐng)不要勉強(qiáng)使用。光纜不可用浸泡方式或高溫高壓方法消毒,如需消毒請(qǐng)用低溫黑蒸或淡酒精擦拭表面的方法進(jìn)行消毒。
To prevent inflexible movement of crystal in the bayonet, please do not force it to be used in case of abnormalities. Optical cables cannot be disinfected by soaking or high-temperature high-pressure methods. If disinfection is required, please use low-temperature black steam or light alcohol to wipe the surface for disinfection.
使用者要細(xì)心記錄光源燈泡的使用時(shí)間,臨近使用壽命時(shí)準(zhǔn)備備用燈泡。光源燈泡有使用壽命的限制,建議不使用時(shí)立即關(guān)閉光源。還有什么問題就來我們網(wǎng)站http://m.tukouzhao.cn咨詢吧!
Users should carefully record the usage time of the light source bulb and prepare a spare bulb as it approaches its lifespan. The light source bulb has a limited lifespan, and it is recommended to immediately turn off the light source when not in use. If you have any further questions, please come to our website http://m.tukouzhao.cn Consult!
s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話:13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國(guó)際信息產(chǎn)業(yè)園6號(hào)樓101-2室
  • 匠仁醫(yī)療湖南長(zhǎng)沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話:13873135765
  • 地址:湖南省長(zhǎng)沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國(guó)際信息產(chǎn)業(yè)園6號(hào)樓101-2室  湖南省長(zhǎng)沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號(hào)