歡迎來(lái)到匠仁醫(yī)療設(shè)備有限公司網(wǎng)站!

更多 > 新聞資訊
公司新聞
行業(yè)知識(shí)
檢測(cè)答疑
圖標(biāo) 首頁(yè) >> 新聞資訊 > 檢測(cè)答疑

檢測(cè)答疑

醫(yī)療用內(nèi)窺鏡設(shè)備定期保養(yǎng)以及清洗維護(hù)

來(lái)源:http://m.tukouzhao.cn/ 發(fā)布時(shí)間:2023-05-23 瀏覽量:0

醫(yī)療用內(nèi)窺鏡設(shè)備定期保養(yǎng)
Regular maintenance of medical endoscope equipment
醫(yī)療用內(nèi)窺鏡設(shè)備定期保養(yǎng)一般由儀管員配合工程技術(shù)人員完成,它是一項(xiàng)不斷循環(huán)進(jìn)行的有組織有計(jì)劃的維修措施,這有利于掌握儀器的運(yùn)行規(guī)律,有利于出現(xiàn)故障后的查找:定期保養(yǎng)的內(nèi)容和時(shí)間,不同儀器有不同的做法.一般可以分3個(gè)等級(jí):
Regular maintenance of medical endoscope equipment is generally carried out by instrument managers in collaboration with engineering technicians. It is an organized and planned maintenance measure that is continuously circulated, which is conducive to mastering the operating rules of the instrument and finding faults. The content and time of regular maintenance vary depending on the instrument. Generally, it can be divided into three levels:
(1)一保:一般可以一個(gè)月至一個(gè)季度進(jìn)行一次.主要內(nèi)容除廠日常維護(hù)的工作外,可以拆開(kāi)機(jī)殼,各處積塵,污垢、異物、緊固螺絲、添加潤(rùn)滑劑;檢查務(wù)器件、元件有無(wú)磨損、變形、燒蝕、擊穿、松動(dòng),受潮,老化、接地等情況;檢測(cè)各組電源電壓及紋波,檢查高壓部件運(yùn)行和接觸情況等;
(1) First maintenance: Generally, it can be carried out once a month to once a quarter. In addition to daily maintenance work in the factory, the main content can be to disassemble the casing, collect dust, dirt, foreign objects, tighten screws, and add lubricants in all places; Inspect the service components for wear, deformation, erosion, breakdown, looseness, moisture, aging, grounding, and other conditions; Detect the voltage and ripple of each group of power supplies, check the operation and contact conditions of high-voltage components, etc;
(2)二保:一般可以半年至一年進(jìn)行一次。主要內(nèi)容除做好一保外,可以對(duì)整機(jī)控制臺(tái)上的各個(gè)儀表及操作控制系統(tǒng)的靈敏度,精度進(jìn)行測(cè)試校正和計(jì)量檢定,更換高壓發(fā)生器絕緣汕等到期的損耗品,對(duì)電路中各測(cè)試點(diǎn)的電壓,波形進(jìn)行系統(tǒng)檢測(cè)和做拉偏試驗(yàn);
(2) Secondary insurance: Generally, it can be carried out once every six months to a year. The main content is not only to ensure the safety of the equipment, but also to test, calibrate, and calibrate the sensitivity and accuracy of various instruments and operating control systems on the control console of the entire machine, replace expired loss products such as high-voltage generator insulation, and conduct systematic testing and bias testing of the voltage and waveform at various test points in the circuit;
內(nèi)窺鏡設(shè)備維修
(3)三保:一般可以2-4年進(jìn)行一次:主要內(nèi)容除做好二保外,必要寸可以將整機(jī)進(jìn)行全部拆卸子以清洗檢修,超過(guò)使用期的元器件應(yīng)盡量更換或修復(fù),應(yīng)對(duì)儀器進(jìn)行較為徹底的調(diào)試,恢復(fù)其工作精度和性能,達(dá)到或超過(guò)新機(jī)的程度是完全有可能的。
(3) Three guarantees: Generally, it can be carried out once every 2-4 years. In addition to ensuring the second guarantee, the entire machine can be fully disassembled for cleaning and maintenance if necessary. Components that exceed the service life should be replaced or repaired as much as possible. The instrument should be thoroughly debugged to restore its working accuracy and performance, and it is entirely possible to achieve or exceed the level of a new machine.
醫(yī)療用內(nèi)窺鏡的清洗維護(hù)
Cleaning and maintenance of medical endoscopes
內(nèi)窺鏡設(shè)備維修人員提醒您,醫(yī)療用內(nèi)窺鏡操作時(shí)動(dòng)作要輕柔,旋轉(zhuǎn)彎曲角手柄要緩慢地操作,用力要均勻,勿用暴力或力量過(guò)大。彎曲部在被“固定”的情況下,不要轉(zhuǎn)動(dòng)彎曲手柄,否則將折斷牽引鋼絲[1]。手持?jǐn)z像頭時(shí),要緊握攝像頭及柄的關(guān)節(jié)位,忌握線(xiàn)束和垂吊關(guān)節(jié)位,否則將損壞玻璃纖維束。
The maintenance personnel of the endoscope equipment remind you that when operating medical endoscopes, the action should be gentle, the bending angle handle should be rotated slowly, and the force should be even. Do not use violence or excessive force. When the bending part is "fixed", do not turn the bending handle, otherwise it will break the traction steel wire [1]. When holding a camera, it is necessary to firmly grasp the joint position of the camera and handle, and avoid grasping the wiring harness and hanging the joint position, otherwise it will damage the fiberglass bundle.
在手術(shù)過(guò)程中光纖內(nèi)窺鏡器械使用后應(yīng)及時(shí)用無(wú)菌水擦凈血跡,切忌將器械拆開(kāi)浸泡以免丟失或體內(nèi)。還有什么事項(xiàng)就來(lái)我們網(wǎng)站http://m.tukouzhao.cn咨詢(xún)!
During the surgical process, the fiber optic endoscope instrument should be promptly wiped clean with sterile water after use, and the instrument should not be opened and soaked to avoid loss or damage to the body. If there are any other matters, please come to our website http://m.tukouzhao.cn consulting service
s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話(huà):13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國(guó)際信息產(chǎn)業(yè)園6號(hào)樓101-2室
  • 匠仁醫(yī)療湖南長(zhǎng)沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話(huà):13873135765
  • 地址:湖南省長(zhǎng)沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號(hào)德邁國(guó)際信息產(chǎn)業(yè)園6號(hào)樓101-2室  湖南省長(zhǎng)沙市雨花區(qū)勞動(dòng)?xùn)|路820號(hào)恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號(hào)